SCUBA Tank-Fill Compressors

Commercial breathing-air systems

Fill SCUBA cylinders with a system built around your operation.

Configure a high-pressure breathing-air compressor for a dive shop, club, school, resort or commercial fill station—with capacity, pressure, storage and controls matched to your real filling demand.

LW 320 ES sound-insulated SCUBA tank-fill compressor

230–700 L/minPublished compressor capacity range
8.1–24.7 cfmSeven complete Silent Series models
200 or 300 barFilling pressure by configuration
Sound insulatedPlus two large retrofit housings

More than a compressor

Plan the complete tank-filling workflow

The right system is determined by more than a horsepower number. Daily cylinder volume, peak demand, starting and final pressure, acceptable fill time, available power, ventilation, storage and operator workflow all affect the recommendation.

LW Americas can configure the compressor with purification, filling hoses or panels, breathing-air monitoring, storage banks and controls selected for the application. Direct filling may suit one operation, while another may benefit from storage to handle busy periods.

LW 570 ES II high-capacity breathing-air compressor with optional filling panel

Built around demand

Commercial SCUBA filling applications

Dive shops and fill stations

Size the compressor and optional storage around typical daily fills, weekend peaks and the customer turnaround your team needs.

Dive schools and clubs

Match capacity, controls and filling connections to training schedules, fleet size and the staff responsible for filling.

Resorts and commercial programs

Plan for recurring demand, remote logistics, equipment-room conditions and the operational redundancy the site requires.

Full Silent Series range

Compare the complete published compressor range

The Silent Series includes seven complete compressor models spanning 230 to 700 L/min, plus sound-insulated retrofit housings for larger LW 720 and LW 1300 systems. The LW 320 ES and LW 570 ES II are highlighted because the LW Americas team identified them as common commercial starting points—not because they are the only available choices.

LW 320 ES commercial SCUBA compressor

LW 320 ES

A common choice for small to midsize dive shops. This sound-insulated, three-stage compressor delivers 320 L/min (11.3 cfm) and is suitable for continuous operation.

View LW 320 ES product details

LW 570 ES II commercial SCUBA compressor

LW 570 ES II

A higher-capacity Silent Series option for busy commercial filling. Its four-stage compressor delivers 570 L/min (20.1 cfm), with optional integrated filling-panel configurations.

View LW 570 ES II product details

Model Capacity Drive power (50/60 Hz) Maximum pressure Published sound at 1 m
LW 230 ES 230 L/min / 8.1 cfm 5.5 / 6.6 kW 350 bar 61 dB(A)
LW 280 ES 280 L/min / 9.9 cfm 7.5 / 9.0 kW 350 bar 62 dB(A)
LW 300 ES III 300 L/min / 10.6 cfm 7.5 / 9.0 kW 350 bar 70 dB(A) ±2
LW 320 ES 320 L/min / 11.3 cfm 7.5 / 9.0 kW 350 bar 62 dB(A) ±2
LW 450 ES III 450 L/min / 15.9 cfm 11.0 / 13.2 kW 350 bar 72 dB(A) ±2
LW 570 ES II 570 L/min / 20.1 cfm 15.0 / 18.0 kW 350 / 420 bar 70 dB(A) ±2
LW 700 ES II 700 L/min / 24.7 cfm 18.5 / 22.2 kW 350 / 420 bar 75 dB(A) ±2

Published LW Americas product-page reference data. The maximum compressor pressure is not the same as the selected cylinder-filling pressure. Filling systems are commonly configured for 200 or 300 bar. Confirm current U.S. electrical, pressure, connection and equipment details in the written quotation.

Large-system sound-insulated housings

The Silent Compressor category also includes retrofit enclosures rather than complete compressor packages. These are intended for larger LW compressor systems.

LW 720 ES housing

Retrofit sound-insulated housing for LW 720 models. Published noise level: 73 dB(A) at 1 m. Dimensions: 2200 × 1630 × 1550 mm.

View LW 720 ES housing

LW 1300 ES housing

Retrofit sound-insulated housing for LW 1300 models. Published noise level: 75 dB(A) at 1 m. Dimensions: 2260 × 1720 × 1450 mm.

View LW 1300 ES housing

Model selection: Capacity alone does not determine the right system. LW Americas should size the compressor, storage, filling equipment, purification and controls around the actual cylinder profile and acceptable fill time.

Configuration options

Build the system your fill station needs

  • Sound-insulated compressor enclosures
  • Automatic condensate drain
  • Automatic stop at final pressure
  • 200 or 300 bar filling configurations
  • Parallel pressure configurations where applicable
  • DIN, CGA and INT connection choices by model
  • Additional filling hoses or filling panels
  • High-pressure storage sized for peak demand
  • Breathing-air purification
  • Puracon filter monitoring options
  • Remote control and monitoring options
  • Electrical configuration matched to available site power

Selection process

What LW Americas needs to recommend a system

Define the cylinders

Share cylinder sizes, valve connections, starting pressure and required final pressure.

Estimate demand

Provide typical daily fills, peak-hour volume and the turnaround time your operation expects.

Review the site

Confirm power supply, equipment-room dimensions, ventilation, intake-air location and operating environment.

Configure the workflow

Select direct fill or storage-assisted filling, hose or panel arrangement, controls and monitoring.

Frequently asked questions

SCUBA tank-fill compressor questions

Which compressor is right for my dive shop?

The LW 320 ES is a common starting point for small to midsize dive shops, while the LW 570 ES II serves higher-demand filling operations. The recommendation should be based on cylinder volume, peak demand, fill time, pressure, storage and available power—not shop size alone.

Can Silent Series compressors fill 200 and 300 bar cylinders?

Published Silent Series compressor packages offer 200 or 300 bar filling configurations, with parallel filling pressures available on applicable models. The final pressure, valve standard, hose and filling connection must be confirmed for the cylinders used by the operation.

What is the difference between maximum pressure and cylinder-filling pressure?

Maximum pressure describes the compressor’s technical capability. The working filling configuration is selected for the intended cylinders and system components. For these common SCUBA applications, LW Americas typically configures 200 or 300 bar filling.

Do I need a high-pressure storage bank?

Not every system requires storage. Storage can improve response during peak demand and reduce the need to wait for direct compressor filling, but it must be sized around the actual cylinder and filling profile.

Can the electrical configuration match my facility?

LW Americas can review configurations across common voltage, frequency and phase requirements. Exact motor, controls and starting requirements depend on the selected compressor and must be confirmed for the installation.

Can Nitrox production be added?

Yes. A compatible NitroxMaker membrane system can be planned with a high-pressure compressor for commercial Nitrox production. The membrane system and compressor must be sized together for the required mixture and production rate.

Start your system review

Request a SCUBA compressor recommendation

Tell us about your cylinders, daily and peak filling demand, desired pressure, available power, storage needs and installation location. LW Americas will help identify the right compressor and filling-system configuration.

Availability, performance, electrical configuration, connections, installation requirements and final specifications must be confirmed in the written quotation and applicable technical documentation.