Industrial high-pressure air supply
Configure high-pressure capacity around the application.
Specify an L&W stationary compressor system around required flow, pressure, duty, power, purification, controls and installation conditions—from 570 to 1300 L/min.
Application-driven selection
Start with the required outcome—not a model number
An industrial high-pressure system must be selected around the required gas, flow, final pressure, operating schedule, available utilities and installation environment. Peak demand may also require storage, filling panels or automatic controls beyond the compressor itself.
LW Americas can review the complete workflow: compression, purification, condensate management, monitoring, storage, controls and the final connection to the application.
Available approaches
Choose the package that fits the operating site
Stationary electric systems
Frame-mounted industrial compressors for facilities with suitable electrical service, ventilation and equipment-room access.
Diesel-powered systems
Evaluate diesel drive for remote locations or sites without suitable electric power, including fuel, exhaust and ventilation requirements.
Sound-insulated systems
Use ES configurations where published sound performance, machinery-room layout and service access are important to the installation.
Industrial model range
Compare verified high-capacity configurations
These models provide starting points across stationary electric, diesel and sound-insulated packages. Final selection and current configuration must be confirmed in the written quotation.
| Model | Configuration | Capacity | Drive | Maximum pressure | Published sound |
|---|---|---|---|---|---|
| LW 570 E II | Stationary electric | 570 L/min / 20.1 cfm | 15.0 kW | 350 / optional 420 bar | 82.7 dB(A) at 1 m |
| LW 570 D | Stationary diesel | 570 L/min / 20.1 cfm | 17.9 kW diesel | 350 / optional 420 bar | 88 dB(A) at 1 m |
| LW 720 E | Stationary electric | 720 L/min / 25.4 cfm | 18.5 kW | 350 / optional 420 bar | 88 dB(A) at 1 m |
| LW 1300 E | Stationary electric | 1300 L/min / 45.9 cfm | 37.0 kW | 350 / optional 420 bar | 89 dB(A) at 1 m |
| LW 570 ES II | Sound insulated | 570 L/min / 20.1 cfm | 15.0 kW | 350 / optional 420 bar | 70 dB(A) ±2 at 1 m |
| LW 700 ES II | Sound insulated | 700 L/min / 24.7 cfm | 18.5 kW | 350 / optional 420 bar | 75 dB(A) ±2 at 1 m |
Published catalogue and current LW Americas product-page reference data. Sound figures and weights may differ between catalogue revisions and current product pages. Confirm current technical data, voltage/frequency and options in the quotation.
Integrated high-pressure systems
Configure more than the compressor
- Breathing-air purification where required
- Automatic condensate drain
- Automatic stop at final pressure
- Oil and temperature monitoring options
- High-pressure storage for peak demand
- Filling panels and multiple pressure arrangements
- Remote control and monitoring options
- Electric configurations matched to site power
- Outlet, hose and connection selection
- Equipment-room airflow and cooling review
- Service-access and maintenance planning
- Application-specific documentation review
Selection process
What LW Americas needs to recommend a system
Define the application
Identify the gas, required outlet quality, flow, pressure and final connection.
Quantify the duty
Provide normal and peak demand, operating schedule, storage needs and acceptable recovery time.
Review the site
Confirm power or fuel, ventilation, ambient conditions, footprint and service access.
Specify the system
Select purification, controls, monitoring, storage and filling interfaces for the workflow.
Frequently asked questions
Industrial high-pressure compressor questions
What industrial capacity is available?
The verified models on this page range from 570 to 1300 L/min, or approximately 20.1 to 45.9 cfm. Select capacity using the actual flow, pressure, duty and storage requirements.
Which models support 420 bar?
Applicable four-stage models publish 350/420 bar technical capability, with 420 bar identified as an optional configuration. Confirm the complete 420-bar system—including downstream components—in the quotation.
Can these compressors run continuously?
Continuous-operation language should be confirmed model by model. The LW 570 E II is specifically described for continuous running and three-shift operation, while other selections require review against the intended duty.
What electrical supply is required?
Published standard configurations commonly show 400 V, three-phase, 50 Hz. Applicable electric models list special voltages and 60 Hz configurations by request. LW Americas should confirm the exact motor, starting method and controls for the site.
Can these systems be installed outdoors?
The reviewed materials do not establish a general outdoor rating or enclosure environmental rating. The installation environment must be reviewed before equipment selection.
Is high-pressure storage required?
Not for every application. Storage may help serve peak demand or reduce waiting time, but it must be sized from the actual consumption or filling profile.
Start your application review
Request an industrial compressor recommendation
Share the application, gas, required capacity and pressure, operating schedule, available power, installation environment, storage needs and connection requirements.
Availability, duty, pressure, electrical configuration, gas compatibility, installation requirements and final specifications must be confirmed in the written quotation and applicable technical documentation.